![]() ![]() Fill to 1/2 inch from top of tank to allow for fuel expansion. Failure to do so will result in death or serious injury. Fuel and vapors are extremely flammable and explosive. Install oil fill cap/dipstick and hand-tighten.ĭANGER: Explosion and Fire. NOTE: Verify oil level often during filling process to ensure overfilling does not occur. Remove dipstick and verify oil level is within safe operating range. To check oil level, remove funnel and insert dipstick into oil filler neck. NOTE: Use petroleum based oil (supplied) for engine breakin before using synthetic oil. Climate determines proper engine oil viscosity. Remove oil fill cap and wipe dipstick clean. Clean area around oil fill and oil drain plug. Add oil slowly and verify oil level often during filling process to ensure overfilling does not occur. NOTE: The generator is shipped without oil in the engine. Failure to do so could result in engine damage. Verify proper type and quantity of engine oil prior to starting engine. Push the button of the protector to reset the circuit protector. NOTE: Continuous tripping of the circuit protector may cause damage to generator or equipment. Reduce the load if the circuit protector is tripped. If this occurs, disconnect all electrical loads to determine the cause of the problem before using the generator again. If the generator is overloaded or an external short circuit occurs, the circuit protector will trip. The DC outlets are protected by a DC circuit protector. The AC outlets are protected by an AC circuit protector. Power LED (green): Indicates output from generator (unless there is a low oil or overload condition).Low Oil Level LED (red): Illuminates when oil level is below safe operating level.If the orange LED returns, contact an IASD. Loads can be applied once the green LED illuminates. If condition was corrected, the orange LED will not illuminate and electrical output will be restored. ![]() To restore electrical output, turn dial OFF to reset. Remove all applied loads and determine if attached devices exceed recommended output power. If LED stays illuminated and the ready LED turns off, the engine will continue to run without output power. During motor starting it is normal for the overload LED to illuminate for a few seconds. Overload LED (orange): Indicates system overload.Off: Best when running a both inductive (motor-starting loads) and resistive (non-motor starting loads), especially when these loads are turning on and off (example: RV, air conditioner, hairdryer).On: The quietest mode and best when running appliances or equipment that are resistive loads (non-motor starting), (example: TV, video game, light, radio).The economy switch has 2 modes of operation: The 5 VDC, 1.5 Amp USB outlet allows charging of compatible electronic devices Eco Mode NOTE: The CHOKE is not required to start a warm engine. The CHOKE position switches the fuel valve on to start the engine.The RUN position is for normal operation and to gradually reduce the use of the choke.The OFF position stops the engine and shuts off fuel flow.This controls the ON/OFF functions, choke and fuel valve operation (Fig. Each outlet will power 120 Volt AC, single phase, 60 Hz electrical loads requiring up to 1700 watts (1.7 kW). The 120 Volt outlet is overload protected by the 15 Amp push button circuit protector. Failure to completely understand manual and product could result in death or serious injury. Read and understand manual completely before using product. User Manual Inverter Generator GENERAL INFORMATION AND SETUP ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |